Observability index — where it appears
Named by 8 essays across 2 fields — each of them below, with the objects they name alongside it.
A ruler and a protractor
What a measurement recovers is decided by the units of its readings. An angle is dimensionless and cannot see a size; a position is not and can. And putting both instruments on one machine recovers no more parameters than the better of them alone — it recovers the same ones six times better conditioned.
How many poses are enough
Three readings determine a four-bar's shape and the thousandth adds almost nothing. The rank is reached at three because there are three parameters, and everything after that is conditioning — which is a different quantity, improves for a different reason, and stops improving much sooner than anybody expects.
Where a calibration should measure
Choose each next pose to make the worst-recovered parameter as observable as it can be, and something happens that nobody asked for: the first three land as far apart as they can get, and every one after that bisects a gap. Nothing told the routine to spread them. It maximises a singular value, and spreading is what that turns out to mean.
What another measurement is worth
The observability of a four-bar's worst-recovered parameter goes 0.118, 0.162, 0.188, 0.208 — and then keeps going up by less and less until adding a pose changes the fourth decimal place. The flattening is not diminishing returns on accuracy. It is a space of fixed dimension being filled.
Four indices, four answers
Five numbers are in use for scoring how well a set of poses determines a mechanism's parameters. They are five different questions about one list of singular values, they rank pose sets differently, and the literature quotes the choice between them as a matter of preference. It is a matter of what the report has to carry.
The instrument's error, multiplied
Repeat a whole calibration on independently noised readings at four levels three decades apart and the error in the recovered shape is linear in the noise, with a fitted slope of 0.9994 and a constant of 1.90. That constant belongs to the mechanism and the poses, not to the instrument — and it is bounded by one over the smallest singular value.
Six things a measurement cannot tell you
A calibration with a perfect residual whose fourth number is a starting guess, a rank that says nothing about a second answer, an improvement that proves nothing about a parameter, a class with no margin, a plan scored on poses that were refused, and a model missing something no data can find. Six claims, each with the number that kills it.
Two instruments disagree about the worst
A protractor recovers three of a four-bar's parameters at a condition number of 5.2. A coordinate machine recovers six at 162. Neither number says which parameter is worst recovered, and when both are asked, they name different ones — because a condition number is a summary of a list and the list is what a report needs.
Named alongside it
The objects these essays reach for when they reach for this one.
CalibrationIdentification jacobianIdentifiableSingular valueNoise amplificationPose selectionLeast-squaresMeasurement residualUnidentifiable directionCognate ambiguityCoupler pointDead centre