Redundant parameter — where it appears
Named by 3 essays across 2 fields — each of them below, with the objects they name alongside it.
An arm's parameters and its poses
A three-link planar arm has three lengths and a tool position that carries a length, so nothing about it is invisible to a measurement — and it is nevertheless the mechanism on this site where a calibration is hardest, because its parameter count is high, its poses are three-dimensional and its Jacobian is singular where a designer likes to work.
Six per joint is two too many
A joint transform is six numbers, and a six-joint arm with a base and tool frame is forty-eight. A measurement can distinguish thirty. The difference is not a saving — it is an eighteen-dimensional set of exactly equivalent answers, and a fit returns whichever member of it the damping prefers.
What a model is allowed to change
Before a calibration runs, somebody decides which numbers it may move. Leave one out and the fit absorbs it into the others; put one in that the instrument cannot see and the fit returns whatever the damping preferred. Both decisions are made before any measurement, both are checkable in advance, and neither is usually checked.
Named alongside it
The objects these essays reach for when they reach for this one.
CalibrationIdentifiableIdentification jacobianMinimal parameterisationSerial chainStructural identifiabilityDH parametersPose selectionSingular configurationSingular valueUnidentifiable directionUnmodelled parameter